SB10150FCT-SB10200FCT

PDF

按此還有更多 10A High Voltage Dual Schottky Barrier Rectifier Diode

PDF File 10A SB10150FCT-SB10200FCT (150V-200V)

Feature Mechanical Data
Schottky Barrier Chip Case: TO-220, Molded Plastic
Guard Ring for Transient Protection Terminals: Plated Leads Solderable per MIL-STD-202, Method 208
Low Forward Voltage Drop Polarity: See Diagram
Low Reverse leakage Current Weight: 2.24 grams (approx)
High Surge Current Capability Mounting Position: Any
Plastic Material has UL Flammability Classification 94V-0 Mounting Torque: 11.5 cm-kg (10 in-lbs) max.
Lead Free: For RoHS / Lead Free Version Add “-LF” Suffix to part Number.
Case: TO-220 Type Voltage Range:  150V~200V Current: 10A
Maximum Ratings and Electrical Characteristics @TA=25 unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load For capacitive load, derate current by 20%.
Characteristics Symbol SB SB Unit
10150CT 10200CT
Peak Repetitive Reverse Voltage VRRM 150 200 V
Working Peak Reverse Voltage VRWM 150 200 V
DC Blocking Voltage VR 150 150 V
RMS Reverse Voltage VR(RMS) 105 140 V
Average Rectified Output Current @TC=95 IO 10 10 A
Non-Repetitive Peak Forward Surge Current 8.3ms Single half sine-wave superimposed on rated load (JEDEC Method) IFSM 150 150 A
Forward Voltage  @IF=5.0A VFM 0.92 0.92 V
Peak Reverse Current  @TA = 25 IRM 0.5 0.5 mA
At Rated DC Blocking Vol. @TA=100 50 50 mA Return Firs Page to Schottky Diode
Typical Junction Capacitance (Note 1) Cj 700 700 pF
Operating and Storage Temperature Range Tj,TSTG -65 to +150
Note 1: Measured at 1.0 MHz and applied reverse voltage of 4.0V D.C.

 

最近更新在 週一, 07 三月 2016 13:07  
歡迎您瀏覽本網站 WELCOME TO MAYLOON
Mayloon Electronic Company Limited Mayloon Lighting Company Limited

Mayloon on-line chat now

即時業務接洽
WhatsApp:91808452
QQ:1247069489
E-mail: peter@mayloon.com
TEL:852-2408 9788 M: 9180 8452

消息

美隆照明有限公司
承接換燈照明工程:
更新換舊
各類型照明燈具
瑩光燈管換LED燈管
包括:燈管支架/有罩燈盤/格柵燈盤等
歡迎來電查詢
MP.:91808452

Newsflash

應急照明 裝置位置

緊急照明

應急照明

 

有圖應急照明 裝置位置

微波感應開關

 

(1)消防應急標誌燈。其位置設在太平門頂部和疏散走道及其轉角處距地面高度1m以下的牆面,採用單應急方式,火災時由消防控制室發出信號接通。

(2)消防應急照明迴路。該迴路的照明平時起正常公共照明的作用,可通過照明開關控制。火災時能轉入應急狀態,直接接通應急疏散照明燈具,此時開關處於失控狀態,消防應急照明不受開關控制。

(3)一般公共照明迴路。此類照明是一般公共照明,不屬應急照明,故可不接在帶蓄電池的迴路,火災時也不要求立即接通。該類照明接在事故照明配電箱的普通迴路可節省單獨設置配電箱的費用,不增加蓄電池的容量,管理比較方便。

(4)根據實際工程需要,應急電源配電箱還可以提供消防控制所需要的直流電源。

(5)對變配電室、消防控制室、消防水泵房、防煙排煙機房,供消防用電的蓄電池室、自備發電機房、電話總機房、計算機房及發生火災仍需堅持工作的重要房間,應單獨設置應急電源箱,應急照明應保證平時正常照明的照度。